Type |
Output voltage |
Output current |
ZI-22 | 12V DC | 2,5A |
ZI-24 | 24V DC | 1,25A |
Attention!
* Below 160V input power supply voltage will continue to stabilize the output voltage, but the maximum output current will decrease concurrent with a decline in input voltage.
* Due to the high frequency converter, some very sensitive radio or microprocessor can operate correctly. It is recommended that you install the filter OP-230 (see item 18) between the power supply and receiver.
* By increasing the load above Imax will stabilize power supply current, but output voltage will decrease. If a outputvoltage falls to about 40% of the power supply is switched off and will be 1.5 ÷ 2sec. sample. Similarly happens when you connect the receiver, which receives a large current boot (ie the cold light bulb). If you're experiencing is not too large, the power supply after a few attempts (eg, the gradual warming-up, the light bulb filaments) runs. If the load is too large to sample the power supply will disconnect the load moment.
Technical data
input voltage | 100÷264V |
output power | 50W |
current limitation | l max= 110% of output current |
minimum load | 0% |
keying frequency | 70kHz |
working temperature | -10÷40°C |
connection | screw terminals 2,5mm² |
dimensions | 6 modules (105mm) |
weight | 190g |
fixing | on rail 35mm |
Electric suppliers
- Product Code: ZI-22-24