Purpose
Power consumption limiters are devised for the automatic disconnection of power from the circuit of single-phase wiring systems once the rated power consumption of the receivers incorporated into the system is exceeded.
 

Functioning
The limiter enables the user to supply power to the circuit if the total consumed power applied to the receivers constituting the system is lower than the preset value on the limiter's scale. Once the rated power consumption threshold in the controlled circuit is exceeded, the element is automatically disconnected from the power source. The supply is reinstated automatically once the preset time lapses. If the value of power consumption remains over the rated input, the power supply to the circuit is cut off again.
The power consumption limiter has been equipped with a delayed activation circuit (1.5÷2sec) which prevents disconnection of the power supply in the event of momentary power consumption surges over the rated level.

Technical data

supply 230V AC
current load <16A
threshold actuation 200÷2000W
hysteresis 2%
activation lag 1,5÷2sec
power supply return  
       OM-1   - factory settings 30sec
       OM-2   - adjustable 4÷150sec
power consumption 0,8W
working temperature -25÷50°C
connection screw terminals 2,5mm²
dimensions 50×67×26mm
fixing two screws to the base

Power consumption limiters

  • Product Code: OM-1 OM-2
  • 0.00€

  • Ex Tax: 0.00€